Back to Verification
Attached Inspection Reports (1):
MLT Test Report 926.8 KB
QAMA NDT INSPECTION
QAMA NDT

QAMA NDT INSPECTION SERVICES

ISO 9001:2015 CERTIFIED QUALITY SURVEILLANCE
Non-Destructive Testing • Third Party Quality Assurance • Heat Treatment • Metallurgy
Corp Office: Kailash Nagar, Industrial Area, Bhilai, Chhattisgarh - 490026
Regd Office: Aurangabad, Bihar • Email: info@qamandt.com • Web: www.qamandt.com
Scan to Verify
Scan to Verify
Certificate of Inspection & Conformance
FIT-FOR-SERVICE / NON-DESTRUCTIVE EXAMINATION CLEARANCE
Certificate No: QAMA/TPI/2026/001
Inspection Date: 12 January 2026
Issue Date: 14 January 2026
PO / WO Ref: BSP/WO/TPI/2026-78 (05 Jan 2026)
Client / Owner: Steel Authority of India Limited (SAIL - BSP)
Project Name: Blast Furnace #7 Shell Welds Overhaul
Job Location: SAIL Bhilai Steel Plant, Bhilai (C.G.)
Client GSTIN: 22AAACS0222M1Z8
Equipment / Component Under Examination
Ultrasonic Testing & Magnetic Particle Inspection of 24 Butt Welded Shell Seams (Plate Thickness 28mm to 36mm, Material IS 2062 E350BR).
Technical Examination Parameters & Applied Standards
Inspection Technique: Ultrasonic Testing (UT) & Magnetic Particle Testing (MPT) Standard / Code Applied: ASME Section V Art. 4 & ASME Section VIII Div. 1 App. 12
Procedure Reference: QAMA/SOP/UT-004 Rev. 2 Calibration Due Date: 15 Dec 2026
Equipment & Probes: Olympus Epoch 600 UFD, 2MHz & 4MHz Angle Beams (45, 60, 70 deg) Calibrated with IIW-V1 Block
Result / Conformance Engineering Remarks & Conclusion
Fit for Service
All examined 24 circumferential and longitudinal shell weld joints comply with ASME Section VIII Div 1 acceptance criteria. No relevant linear or planar flaw indications detected. Structure certified fit for design working pressure for a period of 12 Months.
Attached Test Reports & Verified Engineering Records:
MLT Test Report (land certificate.pdf)
Inspection & Issue Timeline Permanent Non-Destructive Examination Record
Inspected: 12 Jan 2026 • Issued: 14 Jan 2026
Er. Rajesh Kumar Sharma
ASNT NDT Level II (UT/MPT/RT) - Reg #QAMA-L2-892
Inspected & Evaluated By
QAMA NDT Quality Seal
Er. Akhilesh Verma
ASNT NDT Level III (UT/RT/MT/PT/VT) & Lead Auditor - Cert #45102
Authorized Signatory / Approver
This certificate is electronically registered and verifiable online at https://qamandt.com/verify-certificate.php?cert_no=QAMA%2FTPI%2F2026%2F001
Security Verification Hash: 77ad97f2f3a920b82cd35ac8c38353f0129a2043cc6d95a3e249156223a222a9 • Test Report certifies component condition as examined on inspection date.