Universal Certificate Authentication Portal

Verify the genuine authenticity of Industrial Job Inspection Certificates (TPI & NDT) and Student ASNT Level II Credentials issued by QAMA NDT.

Fast instant lookup for plant safety auditors, client procurement desks, and employers

Authentic Industrial Inspection Test Report Verified!

Official Third Party Inspection & Non-Destructive Examination Test Report officially issued by QAMA NDT Services (ISO 9001:2015 Certified). Examination record is permanently valid & verified.

VERIFIED & AUTHENTIC
QAMA NDT
Industrial Job Conformance Record

QAMA/TPI/2026/001

Verification QR Code
Scan with any phone to verify
Inspection Timeline
Inspected: 12 Jan 2026
Issued: 14 Jan 2026
Permanent Test Record
Attached Official Test Reports & Verified Documents
Official examination documents uploaded & verified for this certificate
1 Verified Report
MLT Test Report land certificate.pdf • 926.8 KB
View / Download
Client / Owner Organization
Steel Authority of India Limited (SAIL - BSP)
Bhilai, Chhattisgarh
Project / Site Location
Blast Furnace #7 Shell Welds Overhaul
SAIL Bhilai Steel Plant, Bhilai (C.G.)
Component / Equipment Examined

Ultrasonic Testing & Magnetic Particle Inspection of 24 Butt Welded Shell Seams (Plate Thickness 28mm to 36mm, Material IS 2062 E350BR).

Client PO / WO Ref: BSP/WO/TPI/2026-78 (Dated: 05 Jan 2026)
Inspection Method
Ultrasonic Testing (UT) & Magnetic Particle Testing (MPT)
Standard / Code Applied
ASME Section V Art. 4 & ASME Section VIII Div. 1 App. 12
Inspection Date
12 January 2026
Result Verdict
Fit for Service
Engineering Remarks & Conclusion

All examined 24 circumferential and longitudinal shell weld joints comply with ASME Section VIII Div 1 acceptance criteria. No relevant linear or planar flaw indications detected. Structure certified fit for design working pressure for a period of 12 Months.

Inspected & Evaluated By Er. Rajesh Kumar Sharma ASNT NDT Level II (UT/MPT/RT) - Reg #QAMA-L2-892
Authorized Approver / Director Er. Akhilesh Verma ASNT NDT Level III (UT/RT/MT/PT/VT) & Lead Auditor - Cert #45102

Need Industrial NDT Inspection or ASNT Certification?

Connect with our Level III qualified technical team for fast mobilization and competitive quotes.